请使用支持JavaScript的浏览器!
胶原蛋白、纤连蛋白、玻连蛋白、水性凝胶、低代成纤维细胞
℡ 4000-520-616
℡ 4000-520-616
Advanced BioMatrix/CytoSoft® 6-well Plates//5140-5EA 0.5 kPa
产品编号:5140-5EA0.5kPa
市  场 价:¥2800.00
场      地:美国(厂家直采)
产品分类: 其它>耗材>>
联系QQ:1570468124
电话号码:4000-520-616
邮      箱: info@ebiomall.com
美  元  价:$140.00
品      牌: Advanced BioMatrix
公      司:Advanced BioMatrix ,Inc.
公司分类:
Advanced BioMatrix/CytoSoft® 6-well Plates//5140-5EA 0.5 kPa
商品介绍

Product Description

ThisCytoSoft®6-well plate product has a defined elastic modulus (see certificate of analysis) in a standard flat-bottom 6-well plate. The thickness of the silicone gel is uniform with a ~0.5 mm thick layer of silicone in each well that is fully compatible with mammalian cell cultures. The silicone gels are activated and ready to bind to a purified ECM, such as PureCol® type I collagen (#5005) prior to cell addition. The plates are packaged individually and sterilized, and provided with 5 plates per package.

The rigidity of the substrate to which cells adhere can have a profound effect on cell morphology and gene expression.CytoSoft®products provide a tool to culture cells on substrates with various rigidities covering a broad physiological range. On the bottom of each well, there is a thin layer of specially formulated biocompatible silicone, whose elastic modulus (rigidity) is carefully measured and certified. The surfaces of the gels inCytoSoft®products are functionalized to form covalent bonds with amines on proteins. This chemical functionalization is stable and the reaction does not require a catalyst, facilitating the coating of the gel surfaces with matrix proteins and plating cells.

The silicone substrates ofCytoSoft®products are optically clear and have a low auto-florescence. The layer of silicone in each well is firmly bonded to the bottom of the well. Unlike hydrogels (such as polyacrylamide gels), silicone gels are not susceptible to hydrolysis, do not dry nor swell, are resilient and resistant to tearing or cracking, and their elastic moduli (rigidities) remain nearly unchanged during extended storage periods.

CytoSoft®products accommodate the harvesting of cells using enzymes such as trypsin and collagenase. There is no biochemical breakdown of the substrate during or after enzyme treatment, and there are no residuals of the substrate in the sample retrieved from aCytoSoft®plate.

Parameter, Testing, and MethodCytoSoft®6-Well Plates
Sterilization MethodOzone
PlateSize6-Well Plates
Quantity per Package5Plates
Rigidty (Elastic Modulus)0.2, 0.5, 2, 8, 16, 32, 64 kPa (exact values provided on the CofA)
Storage TemperatureRoom Temperature
Shelf LifeMinimum of 6 months from date of receipt
Plate Surface MaterialFunctionalized Silicone

Growth Area per Well

9.5 cm2

Typical Working Volume per Well

2.0 to 3.5 mL

Cell Attachment Assay

Pass

Directions for Use

Download the full PDF versionor continue reading below:

Coating Procedure

Note:Use these recommendations as guidelines to determine the optimal coating conditions for your culture system.

Remove theCytoSoft®product from the protective sleeve in a sterile hood.

  1. Prepare extracellular matrix material by neutralizing in amine-free buffer pH 7.4 to 7.9 (such as 1X DPBS). We do not recommend using gelatin as your ECM protein.

Note: Pre-warm the coating solution to approximately room temperature before use.

  1. Dilute as needed, and dispense 3 ml of solution into each well to coat the surface.

Note:Recommended dilution for PureCol®Type I collagen is 1:30 (~100 µg/ml).

Note: The hydrophobic surface requires larger volumes to cover the surface than do conventional plastic dishes

  1. Incubate ECM coatedCytoSoft®at room temperature, covered for 0.5-1 hour.
  1. After incubation, aspirate any remaining material and rinse coated surfaces immediately two times with culture medium or PBS. Leave about 2.5 ml of medium per well to keep surface covered.

Note: Do not allow theCytoSoft® surface to become dry once the surface has been wetted.

5. Coated surfaces are ready for use.

Standard harvesting procedures used for removing cells from cultureware can be employed for harvesting cells from theCytoSoft®product including use of trypsin, Accutase® and non-enzymatic cell detachment solutions.

Product Q & A

We recommend a 60X objective for the imaging plates.

The elastic modulus is measured by tracking beads on the gel surface under a wide-field fluorescence microscope without any other specialized equipment. The measurements have small and simple to estimate errors and their results are confirmed by conventional tensile tests. A master curve is obtained relating the mixing ratios of the two components of Sylgard 184 with the resulting elastic moduli of the gels.

Using prewarmed media will decrease gas solubility and help prevent bubbles on the surface of the silicone.

The silicone gel can crack if the surface becomes dry.

No. Cell matrix proteins are attached to the surface of the gel via covalent bonding. It is difficult to form a new ECM layer after cell detachment. There are no longer any reactive groups on the surface of the gel after the initial cell culture.

The change in the refractive index of the silicone distorts things a little, so DIC will be possible but not perfect. Also, DIC is only possible on the glass bottom imaging plates, not the 6-well plastic plates.

1.41

The two main issues are:

1. Ineffecient coating of the matrix proteins due to low pH of the coating solution.

2. Insufficient wash of leftover cell matrix after the coating procedure.

No. Cytosoft must be coated with an ECM protein such as Collagen or Fibronectin.

The surface is decorated with anhydride functional groups.

Plasma use is not recommended. Plasma will induce formation of a hard crust on the surface and will change the mechanical properties of the CytoSoft® products.

Do not freeze the CytoSoft® products.

When frozen, there is a good chance that the silicone surface gets hydrolyzed and absorbs moisture, which would inactivate the binding sites and make the product not-usable.

If you froze the product and it is still frozen, warm the CytoSoft® up at 60C with the bag vented. That will minimize the chance of them absorbing moisture – but there is still a chance that they will no longer be functional.

Using gelatin for coating CytoSoft is often problematic because gelatin often has low molecular weight impurities that block binding sites on the activated surface of the silicone. We recommend using highly purified ECM's instead.

Product Cell Assay

CytoSoft®plates can also be used to show howfibroblastsare able to discriminate between the underlying stiffness. This ismanifested in both adhesion size andstress fibers, as seen below. It appears that the cells on the 8 kPa stiffness havereduced intracellular tension and increasedadhesion.

Product References

References for CytoSoft® Products:

1. Modaresi, Saman, et al. “Deciphering the Role of Substrate Stiffness in Enhancing the Internalization Efficiency of Plasmid DNA in Stem Cells Using Lipid-Based Nanocarriers.”Nanoscale, vol. 10, no. 19, 2018, pp. 8947–8952., doi:10.1039/c8nr01516c.

2. Wilson, Christina L.In Vitro Models Of Brain For Study Of Molecular Mechanisms In Brain Disorder. The University of Nebraska-Lincoln, 2016.

3. Wilson, C. L., Hayward, S. L., & Kidambi, S. (2016). Astrogliosis in a dish: Substrate stiffness induces astrogliosis in primary rat astrocytes.RSC Advances,6(41), 34447-34457. doi:10.1039/c5ra25916a

4. Prager-Khoutorsky M, Lichtenstein A, Krishnan R, Rajendran K, Mayo A, Kam Z, Geiger B, Bershadsky AD. Fibroblast polarization is a matrix-rigidity-dependent process controlled by focal adhesion mechanosensing. Nat. Cell Biol. 2011; 13:1457–1465.

5. Gutierrez E, Tkachenko E, Besser A, Sundd P, Ley K, Danuser G, Ginsberg MH, Groisman A. High Refractive Index Silicone Gels for Simultaneous Total Internal Reflection Fluorescence and Traction Force Microscopy of Adherent Cells. PLoS One. 2011; 6:e23807.

6. Merkel R, Kirchgessner N, Cesa CM, Hoffmann B. Cell force microscopy on elastic layers of finite thickness. Biophys. J. 2007; 93:3314–23.

7. Schellenberg, A. et al. Matrix elasticity, replicative senescence and DNA methylation patterns of mesenchymal stem cells. Biomaterials 35, 6351–8 (2014).

8. Cesa, C. M. et al. Micropatterned silicone elastomer substrates for high resolution analysis of cellular force patterns. Rev. Sci. Instrum. 78, 034301 (2007).

9. Gutierrez, E. & Groisman, A. Measurements of Elastic Moduli of Silicone Gel Substrate with a Micro fluidic Device. Plos One 6 (2011).

10. Mori, H., Takahashi, A., Horimoto, A., and Hara, M. Migration of glial cells differentiated from neurosphere-forming neural stem/progenitor cells depends on the stiffness of the chemically cross-linked collagen gel substrate. Neuroscience Letters, Vol. 555, October (2013)

11. Banerjee, I., Carrion, K., Serrano, R., Dyo, J., Sasik, R., Lund, S. et al.Cyclic stretch of embryonic cardiomyocytes increases proliferation, growth, and expression while repressing Tgf-β signaling.J Mol Cell Cardiol.2015;79:133–144

12. Vertelov, G.et al. Rigidity of silicone substrates controls cell spreading and stem cell differentiation.Sci. Rep.6, 33411; doi: 10.1038/srep33411 (2016).

13. Tkachenko E, Rawson R, La E, et al. Rigid Substrate Induces Esophageal Smooth Muscle Hypertrophy and EoE Fibrotic Gene Expression.The Journal of allergy and clinical immunology. 2016;137(4):1270-1272.e1. doi:10.1016/j.jaci.2015.09.020.

14. Sao, K.et al.Myosin II governs intracellular pressure and traction by distinct tropomyosin-dependent mechanisms.Molecular Biology of the Cell30,1170–1181 (2019).

15.Cooper, J. G.et al.Spinal Cord Injury Results in Chronic Mechanical Stiffening.Journal of Neurotrauma(2019). doi:10.1089/neu.2019.6540

Product Certificate of Analysis

No result for .

Product Videos

link to library blog - What is CytoSoft<sup>®</sup>?
What is CytoSoft®?

Video

link to library blog - How to Coat CytoSoft<sup>®</sup> Plates
How to Coat CytoSoft® Plates

Video

See More

Safety and Documentation

Safety Data Sheet

Certificate of Origin

Product Disclaimer

This product is for R&D use only and is not intended for human or other uses. Please consult the Material Safety Data Sheet for information regarding hazards and safe handling practices.

品牌介绍
美国Advanced BioMatrix(简称ABM) www.advancedbiomatrix.com
Advanced BioMatrix(简称ABM)是美国一家著名的生物公司,获得了Allergan Inc的授权(Allergan用25年时间不断完善胶原蛋白相关的产品的生产工艺),将Allergan的专业和技术用于蛋白生产与检测,致力于为组织工程、细胞分析及细胞增殖等研究领域提供优质稳定的产品。

Advanced BioMatrix不断丰富已有产品线,目前可为三维细胞培养提供各种胶原蛋白、纤连蛋白、玻连蛋白、水性凝胶、不同粘度与分子量的透明质酸以及低代成纤维细胞等。在美国全部产品授权Sigma销售。

Advanced BioMatrix是组织培养,细胞分析和细胞增殖三维(3D)应用的生命科学领域的领导者。 我们的产品被公认为纯度,功能性和一致性的标准。
我们在生产,分离,纯化,冷冻干燥,细胞培养和蛋白质测试,粘附肽,附着因子,底物刚性和其他3D矩阵产品方面拥有丰富的专业知识。 我们的专业技术和知识正在被用来确保我们的产品质量最高,批次之间一致且易于为我们的研究客户使用。

自营商城图标
厂家直采
全球直采 正品优价
正品保障图标
正品保障
厂家直发 有线跟踪
解放采购图标
正规清关
CIF100%正规报关,提供发票
及时交付图标
及时交付
限时必达 不达必赔